- Weight: 67g
- Humidity: 62%
- Operation time: 2-4 months.
- Up to 450 g of the harvest can be dried with the 67-gram pack.
- Weight: 67g
- Humidity: 58%
- Operation time: 2-4 months.
- Up to 450 g of the harvest can be dried with the 67-gram pack
- Applied in ventilation systems for switching ON/ OFF and speed controlling of single phase powercontrolled motors.
- Power supply: 230V
- 300W MAX
- The ECS-9 RJ12 to 4 pin connector cable is a cable to use with Lighting Control Adaptor T (LMA-T) and ThinkGrow LEDs with Threaded Waterproof Connectors for interconnecting.
- The BM-1 weatherproof box is designed for the protection for TrolMaster TS-1/2, HS-1 and ARS-1 controllers from dripping water and low-pressure sprayed water.
- Designed for the protection for TrolMaster TS-1/2, HS-1 and ARS-1
- RJ12 Trolmaster cable set for connecting remote modules
- The ECS-8 extension cable is simply cable to use with the IR emitter in AC Remote station ARS-1 and Digital Day/Night Remote Controller Beta-1
- The ECS-2 cable set is designed to connect Hydro-X to most LED drivers with a pigtail wiring.
- The ECS-5 provides a 5/8” diameter connector for some of Fluence brands newer LED fixtures using PushLock Waterproof Connectors for interconnecting.
- The ECS-3 provides a 5/8” diameter connector for some of Fluence brands LED fixtures using Threaded Waterproof Connectors for interconnecting.
- Applied in ventilation systems for switching ON/ OFF and speed controlling of single phase powercontrolled motors.
- Power supply: 230V
- Rated current: 1.5A
- Dimensions: 95х85х60mm
- Working temperature: 40 ° С
- temperature programming in the range of 16-40 degrees
- accuracy +/-1 degree
- power consumption
- The SPH-1 hub uses a single RJ12 cable input jack, and provides (8) individual RJ12 output jacks that can be connected to various TrolMaster sensors, adapters and device modules.
- Trolmaster MC-1 Multifunction Crimper and Cable Tester is a premium-quality, all-in-one crimp tool, network cable tester, wire stripper and cutter.
- Lighting Control Adapter P (LMA-11) is specially designed for controlling P ballast.
- Lighting Control Adapter D (LMA-12) is specially designed for controlling D ballast.
- Lighting Control Adapter S (LMA-13) is specially designed for controlling S ballast.
- Lighting Control Adapter F (LMA-14) is specially designed for controlling F ballast.
- Lighting Control Adapter DLI (LMA-15) is specially designed for controlling DLI ballast.
- Type of product: Light regulator module
- Supports up to 1000 Gavita e-series devices
- The optional Water Detector WD-2 allows the user to detect water leaks.
- Optional smoke detector for HYDRO-X controller
- Lantern Schedule Adapter (LMA-24) is specially programmed to maintain plants in the vegetative phase.
- Input Voltage: 240 Volts AC
- Output Switch: Relay
- Fuse Rating: 10A/250V~
- AC Power Cord Length: 1.8m
- Temperature Control Range: 40-100°F
- Temperature Deadband: 5°F
- Package Dimensions: 275mm(L) x 87mm(W) x 94mm(H)
- G.W. per pack: 0.56kgs
- The DSV-1 can be addressed to be used as a temperature, humidity, CO2, or timer device module.
- The Trolmaster DSD-1 Dry-contact module provides a simple and flexible solution to who want to connect & control devices to the Hydro-X using a “dry-contact” or relay to activate the device.
- Module for controlling heating or cooling devices
- Module for controlling heating or cooling devices
- The TrolMaster DSH-1 Humidity control / device modules allow user to easily connect and control standard humidifying or dehumidifying devices to the Hydro-x.
- TrolMaster provides the package ECS-500 cable roll for users to customize their own cables
- Model: FC02
- Housing: 130x80x70mm
- Fan Controller: 160x100x90mm
- Dedicated for: 1x200W / TRIAC 1x16A
- Voltage: 230V / 50HZ
- Digital sensor 5V Measures temperatures from –55°C to +125°C (–67°F to +257°F)0.5°C
- Accuracy from –10°C to +85°C
- Protection class: IP54
- Model: FC01
- Housing: 130x80x70 mm
- Fan controller: 145x100x90 mm
- Dedicated for: 1x200W / TRIAC 1x16A
- Voltage: 230V / 50Hz
- Digital sensor: 5V, measures temperatures from -55 °C to +125 °C or from -67 ° F to +257 °F.
- Type of product: Additional ventilation reguator module
- For use in combination with Gavita Master Controller EL-1F / EL-2F
- Input Voltage: 100~240 VAC, 50/60Hz
- Output Current: 10A
- Output Voltage: 100~240 VAC, 50/60Hz
- Working Environments: Temperature 32-122°F, Humidity
- The TS-1 thermostat is designed to replace a thermostat connected to a conventional cool only HVAC unit.
- CO2 device control module
- The TrolMaster DCC-1 provides a simple solution to control a single device, with more than one condition.
- The TrolMaster DCC-1 provides a simple solution to control a single device, with more than one condition.
- The TrolMaster DSP-1 module works as a multi-functional timer
- The TrolMaster 240V DSP-2 module works as a multi-functional timer
- Input Voltage: 240 Volts AC
- Output Switch: Triac
- Fuse Rating: 6A/250V~
- AC Power Cord Length: 1.8m
- Speed Control Range: 25-100%
- Temperature accuracy: +/- 1F
- Package Dimensions: 275mm(L) x 87mm(W) x 94mm(H)
- G.W. per pack: 0.56kgs
- Model: FC11
- Housing:130x80x70mm
- Fan Controller: 160x100x90mm
- Dedicated for: 2A / 2x200W / TRIAC 2x16A
- Voltages: 230V / 50HZ
- Digital sensor 5V Measures temperatures from –55°C to +125°C (–67°F to +257°F) 0.5°C
- Accuracy from –10°C to +85°C
- The TrolMaster DSH-2 Humidity control / device modules allow user to easily connect and control standard humidifying or dehumidifying devices to the Hydro-x.
- The T Lighting Control Adapter (LMA-T) is specially designed to control ThinkGrow LED Panels
- The 4RS-1 is a universal 4-outlet power expansion module. It can be used with any of TrolMaster’s “plug-in” style device modules to expand the number of devices that can be controlled by the Hydro-x.
- The HS-1 from TrolMaster is used to control commercial dehumidifiers.
- Input Voltage: 100~240 VAC, 50/60Hz
- Output Current: 24V 0.2A
- Siren: 85dB
- Strobe: Red, 120 FPM
- Dry Contact Output: 30VDC/250VAC,6A
- Working Environments: Temperature 32-122°F, Humidity
- Input Voltage: 240 Volts AC
- Maximum Current: 0.2A
- Working Environment: Temperature 32-122°F, Humidity=90%
- AC Power Cord Length: 1.8m
- Packaging Dimensions: 275mm(L) x 87mm(W) x 94mm(H)
- Gross Weight: 0.56kgs
- The ARS-1 is a universal controller that works with most mini-split air conditioners (and some window-type AC units too), as long as the unit came with an IR / infrared remote controller.
- The TSH-1 from TrolMaster is used for temperature control or a humidification device that requires a variable input signal of 0-10V.
- Input Voltage: 240 Volts AC
- Output Switch: Relay
- Fuse Rating: 10A/250V~
- AC Power Cord Length: 1.8m
- Humidity Control Range: 20-90%
- Humidity Deadband: 5%
- Package Dimensions: 275mm(L) x 87mm(W) x 94mm(H)
- Gross Weight: 0.56kgs
- The Trolmaster Hydro-X TS-2 thermostat stations is designed to replace a thermostat connected to a standard HVAC unit.
- Gavita Master Controller accessory
- Connect AC fans to the Gavita Master controller
- 240V
- Max current 6A
- Min power 25W
- Max power 1.44 kW
- 3 years warranty
- Voltage: 110-240 V, 50/60 Hz
- Amperage: 0.1A
- Temperature: 32-104°/ 0-40°C
- Humidity: ≤90% Product
- Size: 2.56” / 65 mm(L) x 5.52” / 140 mm(W) x 1.97” / 50 mm(H)
- Weight: 0.66 lbs / 0.3 kg
- Size: 5.12” / 130mm(L) x 7.36” / 187mm(W) x 3.46” / 88mm(H)
- Working Environments: Temperature 32-122°F, Humidity
- 3-in-1 Temperature / Humidity / Light sensor for Hydro-X
- Model: FC12
- Housing: 130x80x70mm
- Fan Controller: 160x100x90mm
- Dedicated for: 2x200W / TRIAC 2x16A
- Voltage: 230V / 50HZ
- Digital sensor: 5V Measures temperatures from –55°C to +125°C (–67°F to +257°F)0.5°C
- Humidity accuracy ±4.5%rh
- Input Voltage: 100~240 VAC, 50/60Hz
- Max Input Current: 0.6A
- Max Output Voltage/Current: 24VDC/0.5A
- Temperature Range: 0-59.0°C
- Temperature Accuracy: ±0.20°C
- Humidity Range: 5-95% rH
- Humidity Accuracy: ±7%
- CO2 Range: 0-2000 PPM
- CO2 Accuracy: ±30 PPM
- Optional CO2 sensor for HYDRO-X controller
- Power supply: 400 mA at 24 VDC
- Burners / Material: 4 precision brass burners
- Power per hour: 2.65 kW
- Recommended gas pressure: 1.15kPa
- Weight: 7.4 kg
- Dimensions: 211 x 511 x 215mm
- Productivity: 0.3 m3 CO2 per hour
- Maximum working area: 113 m3
- Model: HCS-1
- Set includes:
- 1 x Hydro-X Environment Controller
- 1 x Temp / Humid / Light 3-in-1 Sensor
- 1 x RJ12 Cable Set for Light Connection
- Input Voltage: 240 Volts AC
- Output Relay Rating: 10A
- Fuse Rating: 6A/250V~
- AC Power Cord Length: 1.8m
- CO2 Control Range: 400-2000 PPM
- CO2 Deadband Range: 20-200 PPM
- CO2 Accuracy: ±50 PPM
- CO2 Sensor Type: NDIR
- The MBS-PRO 4-in-1 sensor combines a precision air temperature, humidity, CO2 (PPM) sensor and photocell.
- Power supply: 400 mA at 24 VDC
- Burners / Material: 4 precision brass burners
- Power per hour: 5.28kW
- Recommended gas pressure: 1.15kPa
- Weight: 9.9 kg
- Dimensions: 211 x 511 x 364 mm
- Capacity 0.6 m3 CO2 per hour
- Maximum working area: 226 m3
- Working Environment: Temperature 32-122°F, Humidity
- the PPFD sensor will automatically increase or decrease the output level of your supplemental lighting systems
- Voltage: 110-240 V, 50/60 Hz
- Power: ≤100W
- Size: 20.9” / 530 mm(L) x 7.29” / 185 mm(W) x 4.17” / 105.8 mm(H)
- Weight: 22.7lbs / 10.3kg
- Size: 22.51” / 572 mm(L) x 10.31” /265 mm(W) x 7.67” / 195 mm(H)
- Weight: 22.89 lbs / 10.38 kg
- Input Voltage: 100-240VAC, 50/60Hz
- Max Sensors: 13 pcs per Alarm channel
- Max controlled output: 40 pcs
- Working Environment: Temperature 32-122°F, Humidity
- Input Voltage: 100-240VAC, 50/60Hz
- MBS-PRO: max 6pcs per set
- MBS-PAR: max 1pc per set
- Smoke Dectectors / Water Detectors: both max 10 pcs per set
- Temperature Device Stations: max 8pcs per set
- Humidity Device Stations: Mas 8pcs per set
- Model: HCS-2
- Set includes:
- 1 x Hydro-X PRO Environment Controller
- 1 x Temp / Humid / Light / CO2 4-in-1 Sensor
- 1 x RJ12 Cable Set for Light Connection
GSE climate controllers
( number of products: 71 )